3Com 5104M-FIB Switch User Manual


 
SET MODULE CONNECTOR_ NETWORK
2-135
SET MODULE
CONNECTOR_
NETWORK
Use the SET MODULE CONNECTOR_NETWORK command to assign a connector
to a network. This command is available for the ONline 24-Port 10BASE-T
Module and CoreBuilder 5000 connector-switched modules.
The connector-switched modules provide bank-level configuration flexibility
using the TriChannel™ architecture. You can assign either of the two 50-pin
connectors (36-Port Module has three 50-pin connectors), or the entire module,
to any of the Ethernet networks available for modules (or isolated) on the
CoreBuilder 5000 backplane.
For example, with the ONline 24-Port 10BASE-T Module, assigning one
connector to ISOLATED_1 and the other connector to ISOLATED_2 creates two
isolated 12-port subnetworks. Assigning both connectors to the same isolated
network creates a single 24-port isolated network.
Format
Example
The following command sets all ports associated with connector 1 on the
24-Port 10BASE-T Module in slot 7 to Ethernet network 3:
CB5000> set module 7.1 connector_1_network ethernet_3
Module 7.01 connector 1 network ID set to ETHERNET 3.
Related Commands
SET MODULE
SHOW MODULE
set module
connectorslot.
1
connector_
network
_network
slot.
1
Selects a module to assign. Valid values are hub slot 1 through 17,
subslot 1.
connector Selects the connector to which this command applies. Valid values are
1, 2 or 3.
network Selects a network to assign the connector to. Valid values are:
ethernet_1 through ethernet_8
isolated_1 though isolated_8