3Com 5104M-FIB Switch User Manual


 
2-196
SET PORT SQE_TEST
SET PORT SQE_TEST
Use the SET PORT SQE_TEST command to establish if SQE Test is enabled or
disabled for ports on the ONline Ethernet Transceiver Module.
Refer to the ONline Ethernet Transceiver Module Installation Guide for more
information on SQE Test mode and the Ethernet Transceiver Module.
Format
Example
The following command enables SQE Test for port 1 in slot 8:
CB5000> set port 8.1 sqe_test enable
SQE_test on Port 08.01 set to ENABLED.
Related Commands
SAVE MODULE_PORT
SHOW PORT
slot.port Selects a port for SQE test mode setting.
slot (1 through 17) is the slot nubmer location of the module in the
hub and port (1 through 3) is the port number on the specified
module. For example, to specify port 3 on the module with slot ID 6,
enter
6.3
slot.
all
Selects a slot for SQE test mode setting. For example, to specify all
ports on the module with slot ID 6, enter
6.all
enable
Enables SQE test mode. You can connect this port to most devices,
except repeaters. This is the default.
disable
Disables SQE test mode. You can connect this port to baseband
Repeaters and Multiport Transceivers.
set port sqe_test
enable
disable
slot.port
slot.
all