3Com 5104M-FIB Switch User Manual


 
SET TRUNK NETWORK_MAP
2-275
SET TRUNK
NETWORK_MAP
Use the SET TRUNK NETWORK_MAP command to determine if the Network
Map feature should be extended from one hub to the next hub between Token
Ring copper trunk ports. This command is valid for ONLine Token Ring modules
only.
Format
Example
The following command sets the Ring-In port of the Token Ring module in slot 5
to an internal network map, meaning that this port is connected to another
trunk port in the same hub:
CB5000> set trunk 5.1 ring_in network_map internal
Network map state set to INTERNAL.
Related Commands
SHOW TRUNK
SHOW RING_MAP
slot Hub slot 1 through 17.
ring_in
Specifies if the port is a Ring-In port.
ring_out
Specifies if the port is a Ring-Out port.
.trunk port 1 or 2 (required only on Model Number 5202M-FR).
setting External — Ensures a correct port-to-address mapping when you connect
copper trunk ports on modules in different hubs.
Internal — Ensures a correct port-to-address mapping when you connect
copper trunk ports on modules in the same hubs.
set trunk
slot
ring_in
setting
ring_out
network_map
.trunk port