3Com 5104M-FIB Switch User Manual


 
2-74
SET BPORT_LEC ELAN_TYPE
SET BPORT_LEC
ELAN_TYPE
Use the SET BPORT_LEC ELAN_TYPE command to specify the emulated LAN
(ELAN) type associated with the LAN Emulation Client (LEC).
BPORT is an abbreviation for Bridge Port.
LEC ports are logical ports, all of which overlay one physical ATM/Synchronous
Optical Network (SONET) port.
Format
Example
The following command sets the LEC in slot 4, port 1 to type 802.3:
CB5000> set bport_lec 4.1 elan_type 802.3
Bridge Port 04.01 parameter set. Setting saved.
Related Command
SHOW BPORT_LEC CONFIGURATION
slot.lec Identifies the slot and LEC for this operation.
slot (1 through 17) is the slot number and
lec is one of up to 64 LAN
Emulation Clients defined as logical ports for the ATM Backbone
SwitchModule. For example, to identify LEC 32 on the ATM Backbone
SwitchModule in slot 4, enter
4.32
unspecified
Allows the LEC to determine the type of emulated LAN when the LEC
attempts to join the emulated LAN.
802.3
The IEEE 802.3 LAN is the only supported emulated LAN type.
set bport_lec elan_type
unspecified
slot.lec
802.3