SET MODULE PHY_AUTOMATIC_ FAILOVER
SET MODULE
PHY_AUTOMATIC_
FAILOVER
Use the SET MODULE PHY_AUTOMATIC_FAILOVER command in a dual port
configuration to enable or disable the switching over of one physical port to
another physical port in the event that the physical port currently in use
experiences Loss of Frame or Loss of Signal errors.
A PHY is a physical port. Dual ports provide physical redundancy in the event a
physical link or ATM switch fails.
Format
Example
The following command enables the switching over of one PHY to another
when a Loss of Frame or Loss of Signal error occurs:
CB5000> set module 4.1 phy_automatic_failover enable
Phy Automatic Failover set to ENABLED.
Related Commands
SET MODULE PHY_SELECTION
SHOW MODULE
slot.
1
1 through 17. Indicates the slot number of the module you are configuring.
enable
Enables the switching over of the PHY when Loss of Frame or Loss of Signal
errors occur.
disable
Disables the switching over of the PHY when Loss of Frame or Loss of
Signal errors occur.
set module phy_automatic_failover
enable
disable
slot.
1