3Com 5104M-FIB Switch User Manual


 
SET BPORT_LEC ELAN_NAME
2-73
SET BPORT_LEC
ELAN_NAME
Use the SET BPORT_LEC ELAN_NAME command to supply the name of the
emulated LAN (ELAN) associated with the LAN Emulation Client (LEC).
The value of the ELAN name may or may not be taken into account by the LAN
Emulation Configuration Server (LECS) and LAN Emulation Server (LES),
depending on the policy configured on those servers.
BPORT is an abbreviation for Bridge Port.
LEC ports are logical ports, all of which overlay one physical ATM/Synchronous
Optical Network (SONET) port.
Format
Example
The following command sets the elan_name of the LEC in slot 4, port 1 to
Main_lec:
CB5000> set bport_lec 4.1 elan_name
Enter bport_lec 4.1 elan_name:
Main_LEC
Bridge Port 04.01 parameter set.
Related Command
SHOW BPORT_LEC CONFIGURATION
slot.lec Identifies the slot and LEC for this operation.
slot (1 through 17) is the slot number and
lec is one of up to 64 LAN
Emulation Clients defined as logical ports for the ATM Backbone
SwitchModule. For example, to identify LEC 32 on the ATM Backbone
SwitchModule in slot 4, enter
4.32
name Specifies the name (up to 63 characters) of the LAN associated with the
LEC.
set bport_lec elan_name
name
slot.lec