SERIAL CONTROL MODULE: UART
ARM Wakeup Control register
www.digiembedded.com 403
Register
Register bit
assignment
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ARM Wakeup Control register
Address: 9001_1030 / 9001_9030 / 9002_1030 / 9002_9030
Use the ARM Wakeup Control register to enable the ARM wakeup control logic.
13121110987654321015 14
31 29 28 27 26 25 24 23 22 21 20 19 18 17 1630
Not used
Not used
EN
ABLE
BUSY
CHAR
Bits Access Mnemonic Reset Description
D31 R/W ENABLE 0 Force transmit enable
Use this field to force the transmitter to send the character
specified in the CHAR field (D07:00). All user-specified
rules, such as bit order, parity, or number of stop bits, are
enforced.
Write a 1 to enable this field. Hardware clears the field
once the character has been transmitted. Writing a 1 to this
field when it is already a 1 has unpredictable results.
Note: Writing a 1 to this field also clears the FORCE
field in the Interrupt Status register.
D30 R BUSY 0 Read-only busy
Reading a 1 indicates that the force operation you initiated
is in progress.
D29:08 R Not used 0 Write this field to 0.
D07:00 R/W CHAR 0 Force character
Defines the character that is forced out of the transmitter.