HP (Hewlett-Packard) 9500MFP All in One Printer User Manual


 
ENWW 6 Control-panel menus 145
I/O submenu
Items in the I/O (input/output) menu affect the communication between the MFP and the
computer.
Note When a value is specified with an ( * ), that value is the factory (default) setting.
Item Values Explanation
I/O TIMEOUT 5 to 300 Use this item to select the I/O timeout
period in seconds. (The I/O timeout refers
to the time, measured in seconds, that the
MFP waits before ending a print job.)
Use this setting to adjust the timeout for the
best performance. If data from other ports
appears in the middle of your print job,
increase the timeout value.
The factory (default) setting is 15.
PARALLEL INPUT SUBMENU HIGH SPEED
ADVANCED FUNCTIONS
Use this item to specify the attributes for a
parallel connection.
HIGH SPEED: Accepts the faster parallel
communications that are used for
connections with newer computers. The
values for HIGH SPEED include YES and NO.
ADVANCED FUNCTIONS: Turn the bidirectional
parallel communication on or off. The
default is set for a bidirectional parallel port
(IEEE-1284). The values for ADVANCED
FUNCTIONS include ON and OFF, and the
default is ON.
Use this setting to allow the MFP to send
status readback messages to the computer.
(Turning the parallel advanced functions on
might slow the language switching.)
FIND SEND GATESWAYS No value to select. Use this item to initiate a search to find a
valid SMTP server and a valid LDAP server
on the network. AUTO DISCOVER also
configures the two addresses after finding
the valid servers.
SMTP GATEWAY No value to select. Provides the Internet protocol (IP) address
of the SMTP server that processes the e-
mail sent from the MFP.
This address must be configured in order
for e-mail to function.
LDAP GATEWAY No value to select. Provides the IP address of the LDAP server
that provides the address book for e-mail
that is sent from the MFP.
This IP address is optional.
TEST SEND GATEWAYS No value to select. Tests the configured gateways for correct
functionality. If the configured gateways are
functional, GATEWAYS OK appears on the
control-panel display.