HP (Hewlett-Packard) 9500MFP All in One Printer User Manual


 
224 Managing supplies ENWW
13 Using one hand to support the underside of the roller, turn the
roller to a 45° angle and align the roller with the slot. Slide the
roller into the slot until it stops completely.
14 Swing the green lever up. Close all of the doors.
Note
If the lever does not move freely, make sure that the transfer roller
and the transfer belt are pushed into the MFP completely.
15 On the right side of the MFP, pull the blue tab to remove the
old filter from the slot.
16 Remove the new filter from its packaging and insert the filter
into the slot.
Note
Do not print without a filter installed.
17 Remove the new tray rollers from their packaging. Avoid
touching the rubber surface of the rollers.
Note
Replace all of the rollers in a tray at the same time.
18 Pull tray 2 out of the MFP until it stops. Lift it up slightly and
pull it out. Remove tray 3, noting which tray belongs in which
position.
Note
Do not move the blue switch at the left rear of the tray. It is not
necessary to unload the paper from the tray.
14
15
16
17
18
13