Hyundai HI4 Robotics User Manual


 
3. Service menu
━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━
----------------------------------------------------------------------------------------
3 - 72
(2) Cycle time : Number of the cycle played during the operation time. it is counted
at the step 1. And through the robot is stopped during operation, counting is
continued. (It is reset as exceeding 255 times)
(3) GUN ON Time : Gun signal output time per one cycle during operation.
(After the lamp is on, it is reset after 24 hours)
(4) GUN ON count: Gun On signal output per 1 cycle in the operation.
( After the lamp on, it is reset as exceeding 65535 times.)
3.7.2.2 Total Run time
Outline
Total amount of the operation time after power on. Total cycle time, total GUN ON time,
and total Gun On count are as above, too.
Screen display
3.7.2.3 Operation time reset
Outline
(1) Clear all data ..... All data is cleared
(2) Clear run time ..... Total work time is cleared.
(3) Clear cycle count ..... Total cycle time is cleared
(4) Clear gun data ..... Total GUN ON time and count are cleared.
Operation method
The following is displayed as selecting 3: Clear all data, 4: Clear run time, 5: Clear
14:39:38 *** Run time *** A:0 S:4
*Total run time =0:0: 0.00
Total cycle count =0
GUN1 time =0:0: 0.00 count=0
GUN2 time =0:0: 0.00 count=0
GUN3 time =0:0: 0.00 count=0
GUN4 time =0:0: 0.00 count=0
DI Sig waiting time =0:0: 0.00
Timer waiting time =0:0: 0.00
Press
[
ESC
]
or
[
R..
]
>