Hyundai HI4 Robotics User Manual


 
7. R code
------------------------------------------------------------------------------------------------
----------------------------------------------------------------------------------------
7
- 34
7.34 (34) R310 MANUAL OUTPUT OF GO-SIGNAL
Outline
It outputs 8 signals as 1 group at the same time.
Operation method
After inputting the group No. with a numeric key, if press [SET] Key, it will be appeared
on the screen as followings.
After inputting the data with a numeric key, press [SET] key.
Reference
⑴ It can not be executed during operation.
⑵ The displayed value before changing the numerical value displays the current setting
status.
Enter Grou
p
number
(
1 - 32
)
>R310
,
10
Service System Rel.WAIT Cond Set
In
p
ut data to be out
p
ut manuall
y
(
0-255
)
>R310
,
10.255
Service System Rel.WAIT Cond Set