396 Hardware Reference Manual
Intel
®
IXP2800 Network Processor
Performance Monitor Unit
11.4.6.3 IXP2800 Network Processor MSF Events Target ID(000011) /
Design Block #(0110)
63 Hash Cmd_Pipe Full P_CLK single separate Hash Command Pipe Full
64
Hash Push_Data_Pipe
Not_Empty
P_CLK single separate Hash Push Data Pipe Not Empty
65 Hash Push_Data_Pipe Full P_CLK single separate Hash Push Data Pipe Full
Table 156. SHaC PMU Event List (Sheet 4 of 4)
Table 157. IXP2800 Network Processor MSF PMU Event List (Sheet 1 of 6)
Event
Number
Event Name
Clock
Domain
Pulse/
Level
Burst Description
0
inlet command FIFO
enqueue
P_CLK pulse separate
1
inlet command FIFO
dequeue
P_CLK pulse separate
2 inlet command FIFO full P_CLK level separate
3
inlet command FIFO not
empty
P_CLK level separate
4
read command FIFO
enqueue
P_CLK pulse separate
5
read command FIFO
dequeue
P_CLK pulse separate
6 read command FIFO full P_CLK level separate
7
read command FIFO not
empty
P_CLK level separate
8
write command FIFO
enqueue
P_CLK pulse separate
9
write command FIFO
dequeue
P_CLK pulse separate
10 write command FIFO full P_CLK level separate
11
write command FIFO not
empty
P_CLK level separate
12
S_PULL data FIFO 0
enqueue
P_CLK pulse separate
13
S_PULL data FIFO 0
dequeue
P_CLK pulse separate
14 S_PULL data FIFO 0 full P_CLK level separate
15
S_PULL data FIFO 0 not
empty
P_CLK level separate
16 Received Data Training P_CLK level separate
17 Received Calendar Training P_CLK level separate
18
Received Flow Control
Training
P_CLK level separate