Dell 6.2 Server User Manual


 
338 | VirtualAPs DellPowerConnectW-SeriesArubaOS6.2 | User Guide
Parameter Description
is set to either 'Passive' or 'Active-All channels') - 0 (when Measurement Mode is set to 'Bea-
con Table') - 255 (when Measurement Mode is set to 'Active-Channel Report')
Randomization Interval This value is used to set the Randomization Interval field in the Beacon Report Request
frame. The Randomization Interval is used to specify the desired maximum random delay in
the measurement start time. It is expressed in units of TUs (Time Units). A Randomization
Interval of 0 in a measurement request indicates that no random delay is to be used. This
field can be given a value in the range (0, 65535). The default value is 0.
Measurement Duration This value is used to set the Measurement Duration field in the Beacon Report Request
frame. The Measurement Duration is set to the duration of the requested measurement. It is
expressed in units of TUs. This field can be given a value in the range (0, 65535). The default
value is 0.
Measurement Mode for
Beacon Reports
Click the Measurement Mode for Beacon Reports drop-down list and specify one of the
following measurement modes:
l active—Enables active beacon measurement mode. In this mode, the client sends a
probe request to the broadcast destination address on all supported channels, sets a
measurement duration timer, and, at the end of the measurement duration, compiles all
received beacons or probe response with the requested SSID and BSSID into a
measurement report.
l beacon-table—Enables beacon-table beacon measurement mode. In this mode, the
client measures beacons and returns a report with stored beacon information for any
supported channel with the requested SSID and BSSID. The client does not perform any
additional measurements.
l passive—Enables passive beacon measurement mode. In this mode, the client sets a
measurement duration timer, and, at the end of the measurement duration, compiles all
received beacons or probe response with the requested SSID and BSSID into a
measurement report.
NOTE: If a station doesn't support the selected measurement mode, it returns a Beacon
Measurement Report with the Incapable bit set in the Measurement Report Mode field.
Default Mode: beacon-table
Reporting Condition This option is used to indicate the value for the "Reporting Condition" field in the Beacon
Reporting Information sub-element present in the Beacon Report Request frame. It can have
a range from 0 to 255. The default value is 0.
ESSID name This option is used to indicate the value for the "SSID" field in the Beacon Report Request
frame. It corresponds to the SSID Name for which the Beacon Report Request frame needs
to be generated. It is a string with a minimum length of 1 and a maximum length of 32.
Reporting Detail This option is used to indicate the value for the "Detail" field in the Reporting Detail sub-ele-
ment present in the Beacon Report Request frame. It is set to "Disabled" by default.
Measurement Duration
Mandatory
This value is used to set the "Duration Mandatory" bit of the Measurement Request Mode
field of the Beacon Report Request frame. The default value is "Disabled".
Request Information
values
This option is used to indicate the contents of the Request Information IE that could be
present in the Beacon Report Request frame. The Request Information IE is present for all
Measurement Modes except the 'Beacon Table' mode. It consists of a list of Element IDs that
should be included by the client in the response frame.
To select the information to be sent in beacon report requests using the command-line interface, access the CLIin
config mode and issue the following commands.
wlan bcn-rpt-req-profile <profile>
channel <channel>
clone <profile>
interface <interface>
measure-dur-mandatory