3Com CM 4000 Switch User Manual


 
Configurator
MPK Devices
5−110 CM 4000 Installation and Operating Manual
With the exception of the CP 3800 Series panels, RP 1/2/3, RP 1/2/3 C, and SlimLine Under Monitor Dis-
plays, device addresses such as “00000018” are determined at time of manufacture and cannot be changed by
the user. To display the address of a control panel, please see Display Control Panel ID on page 6−21.
Input Sets
Name of CP Input Set to be assigned to this device. The usual practice is to have one CP Input Set,
containing the names of all inputs, apply to all panels. However, special CP Input Sets could be created which
list only selected inputs; such a set could be used to prevent certain panels from selecting specific inputs.
Creation of CP Input Sets was described on page 5−62.
If panel “A” does not have access to a certain input, but that input has been selected by panel “B” for the output
presently being statused by panel A, then panel A has no way of reporting the mnemonic of the input. Under
these conditions, panel A will show asterisks (****) for status.
For each CP 3832 or CP 3864 (including type L) operated as a:
Single−bus control panel, select the name of the CP Input Set that will be used to assign sources to the control
panel’s input buttons.
—“Split” panel, with some of the buttons used as inputs and some as outputs, select the name of the CP Input Set
that will be used to assign sources to the control panel’s input buttons.
Main source panel (controlling the inputs at a multi−panel control station) select the name of the CP Input Set
that will be used to assign inputs to the buttons at this control station. See page 5−127 for more information
about CP 3832/64 multi−panel control stations.
In Panel
This column is used only for expansion panel configuration when that panel will be used for addi-
tional inputs.
For each CP 3832 or CP 3864 operated as an expansion input panel (used in association with a main source
panel), select the MPK Devices name of the associated main panel in this column. See page 5−127 for more
information about CP 3832/64 multi−panel control stations.
Note 1: In some cases you will need to press “Apply” to update the selections in drop down lists.
Out Set
CP Output Set name. Creation of CP Output Sets was described on page 5−78.
If the entry is an actual CP Output Set, then the control panel will be able to control all the outputs listed in that
Set. Depending on the contents of the set, this would allow for full−matrix or multi−bus control.
For many single−output panels, this field can be used to enter the name of a single switcher output to be con-
trolled (see Note 2 below for exceptions). The source of the output names is the Switcher Output table (page
5−55).
Note 2: For a CP 300, CP 310, CP 320,or single−bus CP 330 (including “/S” type) control panels, for a
CP 3020 panel, and for a single−bus CP 3830, enter the name of the output set that contains the name of
the output to be controlled.