3Com CM 4000 Switch User Manual


 
Control Panel Operation
CP 3800
6−58 CM 4000 Installation and Operating Manual
SEQ
SEQUENCE MODE (CONT’D)
Entering Define Mode
The panel is placed in Define Sequence mode by double punching the SEQUENCE button, which will then illuminate in red
to indicate this mode. The display will indicate this mode and prompt for a button assignment (valid soft key locations will
illuminate in green):
1 Defining Sequence − Use Up/Down Buttons and Soft Key to Select Position
BLACKSEQ BARS_SEQ SEQ_A SEQ_B USRSEQ05 USRSEQ06 USRSEQ07 USRSEQ08
Figure 6−87. Example Home Defining Sequence Menu.
Creating the Sequence Definition
When the user has selected an appropriate location, that soft key will illuminate in red and the display will indicate the selec-
tion and that it is ready to record the sequence:
3 Defining Sequence <USRSEQ21> − Select TAKE to Define − Press SEQ to Finish
TST_SQ17 TST_SQ18 USRSEQ20 −DEFINE−
Figure 6−88. Example Sequence Definition Menu − Page 3, Fifth Button Position Selected.
When this menu appears the user may deselect the red soft key or select CLEAR to return to the Home Defining Sequence
menu or may deselect the red SEQUENCE button to exit Defining mode.
To create the definition, the operator selects TAKE. The panel returns to single or multiple destination home mode (wherever
it was) and the Sequence button blinks in red to indicate that a definition is in progress.
In multiple destination mode the user is then prompted to select a sequence output and a source:
3 Select Sequence Outputs, Then Select Source
VTR_01 VTR_02 VTR_03 ENGNRING STUDIO_A STUDIO_D MONITR45 MONITR46
Figure 6−89.