COPYRIGHT
©
1999 CANON INC. CANON imageRUNNER 600 REV.1 JAN. 2000 PRINTED IN U.S.A.
6-51
CHAPTER 6 IMAGE FORMATION SYSTEM
2. Removing the Photosensitive
Drum
1) Open the front cover.
2) Slide out the process unit. (See Figures 6-
D701 through -D703.)
3) Remove the three screws [1], and discon-
nect the three connectors [2]; then, detach
the auxiliary plate [3].
4) Remove the two screws [4], and detach
the positioning holder [5].
Figure 6-A701
Figure 6-A702
[1]
[1]
[1]
[3]
[2]
[2]
[2]
[5]
[4]