COPYRIGHT
©
1999 CANON INC. CANON imageRUNNER 600 REV.1 JAN. 2000 PRINTED IN U.S.A.
13-223
CHAPTER 13 TROUBLESHOOTING
<FIXING>
Executing Auto Adjustment for Fixing Assembly-Related Items
Level 3
NIP-
CHK
Description
Generating a Fixing Nip Width Measurement Print
Operation
1) Make about 20 copies of the Test Sheet in A4.
2) Set A3 paper on the manual feed tray.
3) Select NPP-CHK to highlight, and press the OK key.
• The paper will be picked up and stopped between the
fixing rollers; then, it will be discharged in about 20
sec.
4) Measure the width as indicated.
Caution:
a and c are points 10 mm from both ends of paper.
Remarks
Feeding
direction
Standard:
|a-c| = 0.5 mm or less
Standard:
7.3±0.5 mm
c
a
Middle of
copy
paper
b
A3 paper
COPIER>FUNCTION