COPYRIGHT
©
1999 CANON INC. CANON imageRUNNER 600 REV.1 JAN. 2000 PRINTED IN U.S.A.
11-31
CHAPTER 11 INSTALLATION
10) Connect the power supply unit to the
power plug, and check to make sure that
LED1 [14] (green) on the PCB of the con-
troller turns on.
11) Execute RAM clear. Set the bits of the
DIP switch [15] (SW2) on the PCB of the
controller as shown in the following table,
and push the push switch [16] (SW4) so
that LED5 [17] (red) turns on.
Figure 11-511
Figure 11-510
LED1 LED2LED3
2
1
LED5
LED6
LED4
IC6
SW1
SW4
SW3
6
1
BAT1
CN4
1
2
CN3 CN2
SW2
[14]
LED1LED2 LED3
2
1
LED5
LED6
LED4
IC6
SW1
SW4
SW3
6
1
BAT1
CN4
1
2
CN3 CN2
12345678
SW2
[15]
[16]
[17]
SW2 bits
SW2-1
SW2-2
SW2-3
SW2-4
SW2-5
SW2-6
SW2-7
SW2-8
Setting
OFF
OFF
ON
ON
OFF
OFF
See step 8).
OFF