COPYRIGHT
©
2000 CANON INC. CANON imageRUNNER 600 REV.1 JAN. 2000 PRINTED IN U.S.A.
8-13
CHAPTER 8 FIXING SYSTEM
B. Down Sequence Control
Part 2>Chapter 7>3.3
Figure 8-302 Down Sequence
Main heater(H1)
Sub heater(H2)
Copying speed
200
˚C
195
˚C
190
˚C
185
˚C
180
˚C
175
˚C
170
˚C
165
˚C
160
˚C
60cpm 60cpm50cpm 40cpm
Stopped
STBY PRINT PRINTSTOP
Copy
Start key
ON
Controlled to 200˚C
At 175˚C, dropped to
50 cpm.
At 170˚C, dropped to
40 cpm.
At 165˚C, printing stopped.
At 200˚C, printing is resumed automatically.
The sub heater is also turned
on to recover temperature.
Related Service Mode
COPIER>OPTION>BODY>FIX-TMP1
(down sequence state temperature)
Set a relatively high temperature for users
who prefer priority on image quality, and a
relatively low temperature for users who prefer
priority on productivity.
Setting
0
1
2
3
4
5
50cpm
170˚C
175˚C
180˚C
185˚C
190˚C
195˚C
40cpm
165˚C
170˚C
175˚C
180˚C
185˚C
190˚C
Stop
160˚C
165˚C
170˚C
175˚C
180˚C
185˚C
Resume
175˚C
180˚C
185˚C
190˚C
195˚C
200˚C