6-78
COPYRIGHT
©
1999 CANON INC. CANON imageRUNNER 600 REV.1 JAN. 2000 PRINTED IN U.S.A.
CHAPTER 6 IMAGE FORMATION SYSTEM
Figure 6-F709
Caution:
When mounting the cleaning blade, be
sure to put the blade auxiliary plate be-
tween the blade support plate and the
blade back plate.
Caution:
After mounting the cleaning blade, turn
the drum; if toner slips off the cleaning
blade at this time, repeat the foregoing
steps.
If the problem is not corrected after
tightening the screws, replace the clean-
ing blade.
Blade support plate
Blade auxiliary plate
Blade back plate