COPYRIGHT
©
2000 CANON INC. CANON imageRUNNER 600 REV.1 JAN. 2000 PRINTED IN U.S.A.
6-65
CHAPTER 6 IMAGE FORMATION SYSTEM
Figure 6-C714
Reference:
The height of the charging wire for the primary assembly and the transfer charging assembly
may be adjusted by turing the screw found on the back of the assemblies. A single turn of the
screw changes the height by about 0.7mm.
6. Adjusting the Height of the Charging Wire
Primary
Height of the charging wire
No height adjusting
mechanism
Charging assembly
Pre-transfer
Transfer
Separation
7.5
- 0mm
+ 3mm
7.5
- 0mm
+ 3mm
13.6±0.3mm
15.7
±
0.2mm
10
±
0.2mm