CHAPTER 3 ORIGINAL EXPOSURE SYSTEM
Related Error Code
[1] While in standby, the scanning lamp turns on. (detected in reference
to the voltage of FL-DTCT)
[2] During scanning, the scanning lamp turns off. (detected in reference
to the voltage of FL-DTCT)
E220
(activation error)
[1] When the main power switch is turned on, the temperature does not
reach 70˚C or higher 5 min after the scanner heater has turned on
(HEAT-ON=1).
[2] While power is supplied, the temperature does not reach 75˚C or
more 3 min after the fluorescent lamp heater has turned on.
E222
(fluorescent lamp heater
error)
[1] When the main power switch is turned on, the temperature does not
reach 10˚C or higher 2 min after the fluorescent heater has turned
on (HEAT-ON=1).
[2] While power is supplied, a temperautre of 0˚C or lower is detected.
E211
(thermistor open circuit)
While the scanning lamp is off, a temperature of 170˚C or more is
detected.
E215
(thermistor short circuit)
While the scanning lamp is on, a temperature of 170˚C or higher is
detected by the thermistor.
E219
(scanning lamp end of life)