COPYRIGHT
©
1999 CANON INC. CANON imageRUNNER 600 REV.1 JAN. 2000 PRINTED IN U.S.A.
13-169
CHAPTER 13 TROUBLESHOOTING
Remarks
Unit: °C
Unit: %RH
Unit: °C
Level 3
TEMP
HUM
OPTICS
FIX-C
FIX-E
Description
Indicates the machine internal temperature (detected by the
environment sensor).
Indicates the machine internal relative humidity (detected by
the environment sensor).
Indicates the temperature of the scanning lamp (indicated by
the fluorescent lamp sensor).
Indicates the temperature at the middle of the upper fixing
roller (detected by the main thermistor TH1).
Indicates the temperature of the ends of the upper fixing
roller (detected by the sub thermistor TH2).
<ANALOG>
Indicates the readings of analog sensors.
Remarks
The paper width is shown
as a whole number,
omitting decimal places.
Level 3
WIDTH-
C3
WIDTH-
C4
WIDTH-
MF
Description
Indicates the paper size for the cassette 3.
Indicates the paper size for the cassette 4 .
Indicates the paper size and the paper width (mm) for the
manual feed tray.
COPIER>DISPLAY
<CST-STS>
Indicates the use of the cassette and the manual feed tray.