Canon DU7-1100-010 Printer User Manual


 
CHAPTER 13 TROUBLESHOOTING
13-250
COPYRIGHT
©
2000 CANON INC. CANON imageRUNNER 600 REV.1 JAN. 2000 PRINTED IN U.S.A.
IX . SELF DIAGNOSIS
The microprocessor on the copier’s DC controller PCB is equipped with a mechanism that
checks the state of the copier (especially its sensors). It runs a check as needed and, upon detection
of a fault, indicates a code on the control panel.
A. Copier Self Diagnosis
Code Cause
The main thermistor (TH1) has poor
contact or an open circuit.
The fixing heater (H1, H2) has an open
circuit.
The thermal switch (TS1) has an open
circuit.
The SSR is faulty.
The DC control PCB is faulty.
The sub thermistor (TH2) has poor
contact or an open circuit.
After indicating E000, the power switch
turns off in about 5 sec.
The main thermistor (TH1) has a short
circuit.
The SSR is faulty.
The DC controller PCB is faulty.
The sub thermistor (TH2) has detected
overheating.
The main thermistor (TH1) has poor
contact or an open circuit.
The fixing heater (H1, H2) has an open
circuit.
The thermal switch (TS1) has an open
circuit.
The SSR is faulty.
The DC controller PCB is faulty.
The main thermistor (TH1) has poor
contact or an open circuit.
The fixing heater (H1, H2) has an open
circuit.
The thermal switch (TS1) has an open
circuit.
The SSR is faulty.
The DC controller PCB is faulty.
The SSR is faulty.
The DC controller PCB is faulty.
The cleaning belt inside the fixing
assembly has been taken up.
The fixing cleaning belt length sensor
(PS7) is faulty.
The DC controller PCB is faulty.
Description
The temperature of the upper fixing
roller does not reach 70°C within 3 min
30 sec after power-on.
The temperature of the upper fixing
roller exceeds 230°C for 2 sec or more.
The difference in detection temperature
between the main thermistor (TH1) and
the sub thermistor (TH2) is 50°C for 1
sec or more.
The temperature of the upper fixing
roller does not reach 100°C within 2.5
min after it has exceeded 70°C.
The temperature of the upper fixing
roller does not reach 150°C within 2.5
min after it has exceeded 100°C.
The temperature of the upper fixing
roller drops to 70°C or less for 2 sec
after it has reached 100°C.
The SSR used to drive the fixing heater
has a short circuit.
The cleaning belt inside the fixing
assembly has been taken up more than a
specific length.
E000
(NOTE 1)
E001
(NOTE 1)
E002
(NOTE 1)
E004
(NOTE 1)
E005
(NOTE 1)
E003
(NOTE 1)