COPYRIGHT
©
1999 CANON INC. CANON imageRUNNER 600 REV.1 JAN. 2000 PRINTED IN U.S.A.
6-75
CHAPTER 6 IMAGE FORMATION SYSTEM
Figure 6-F701
Figure 6-F702
Separation claw
Cleaning blade
[1]
[2]
F. Drum Cleaner Unit
Construction
1. Removing the Cleaning Blade
1) Open the front cover.
2) Slide out the process unit.
3) Remove the screw [1], and detach the re-
ciprocating arm [2].