6-76
COPYRIGHT
©
1999 CANON INC. CANON imageRUNNER 600 REV.1 JAN. 2000 PRINTED IN U.S.A.
CHAPTER 6 IMAGE FORMATION SYSTEM
4) Disconnect the connector [3], and remove
the five screws [4]; then, while pushing it
toward the rear, detach the cleaning blade
together with the mounting plate [5].
5) Remove the E-ring [6], and detach the
pressure plate [7]; then, detach the clean-
ing blade assembly [8].
6) Remove the five screws [9], and detach
the blade retaining plate [10]; then, detach
the cleaning blade [11].
Figure 6-F703
Figure 6-F704
Figure 6-F705
[4]
[5]
[3]
[6]
[7]
[8]
[10]
[11]
[9]