COPYRIGHT
©
1999 CANON INC. CANON imageRUNNER 600 REV.1 JAN. 2000 PRINTED IN U.S.A.
8-47
CHAPTER 8 FIXING SYSTEM
4. Removing the Reversal Sensor
1) Remove the fixing assembly from the
copier.
2) Open the upper delivery assembly; then,
remove the screw [1], and detach the re-
versal sensor [2].
5. Removing the Fixing/Feeding Unit
Outlet Sensor
1) Remove the screw [1] from the bottom of
the fixing/feeding unit, and detach the fix-
ing/feeding outlet sensor [2].
Figure 8-G504
Figure 8-G505
[1]
[2]
[2]
[1]