CHAPTER 13 TROUBLESHOOTING
13-254
COPYRIGHT
©
1999 CANON INC. CANON imageRUNNER 600 REV.1 JAN. 2000 PRINTED IN U.S.A.
Code Cause
The fluorescent lamp is mounted
wrongly.
The fluorescent lamp is faulty.
The fluorescent lamp heater inside
thermistor is faulty.
The fluorescent lamp is faulty.
The light intensity sensor is faulty.
The intensity control PCB is faulty.
The inverter PCB is faulty.
The DC controller PCB is faulty.
The fluorescent lamp is faulty.
The light intensity control PCB is
faulty.
The DC controller PCB is faulty.
The wiring is faulty (short circuit, open
circuit).
The scanner cooling fan (FM3) is faulty.
The DC controller PCB is faulty.
The wiring is faulty (short circuit, open
circuit).
The DC controller PCB is faulty.
The image processor PCB is faulty.
The original orientation detection PCB
is faulty.
The DC controller PCB is faulty.
The control panel PCB is faulty.
The inverter cooling fan (FM9) is faulty.
The DC controller PCB is faulty.
The wiring is faulty (short circuit, open
circuit).
Description
The absence of the fluorescent lamp is
detected at power-on.
The temperature around the fluorescent
lamp is 170°C or more while the
fluorescent lamp is on.
The light intensity does not reach a
specific level within 10 sec after the
fluorescent lamp has been turned on.
The activation detection signal (FL-
DTCT) arrives within 5 sec after the
fluorescent lamp has been turned off.
The activation detection signal (FL-
DTCT) does not arrive within 60 se after
the fluorescent lamp has been turned on
during shading adjustment.
The light intensity does not reach a
specific level within 10 sec after the
fluorescent lamp has been turned on.
(However, within 60 sec if the room
temperature is 10°C or less.)
The activation signal is not turned off 5
sec after the fluorescent lamp has been
turned off.
The activation signal does not arrive with
60 sec after the fluorescent lamp has
been turned on during shading
adjustment.
The lock signal (FM3LCK) is detected
for 5 sec or more while the scanner
cooling fan (FM3) is being driven.
An error in communication occurs in the
microprocessor on the DC controller
PCB.
The orientation of the original is not
identified when the second or subsequent
original must be read.
The orientation of the last original is not
detected 5 sec or more after the last
original has been read.
A communication error has occurred
between the microprocessor on the DC
controller PCB and the microprocessor
on the control panel PCB.
The lock detection signal (FM9LCK) is
generated 5 sec or more while the
inverter cooling fan (FM9) is being
driven.
E218
E219
E220
E222
E226
E240
E241
E243
E251