COPYRIGHT
©
1999 CANON INC. CANON imageRUNNER 600 REV.1 JAN. 2000 PRINTED IN U.S.A
3-17
CHAPTER 3 ORIGINAL EXPOSURE SYSTEM
Figure 3-A504
Figure 3-A505
Figure 3-A503
[8]
[9]
[7] [8]
Cut-off (front)
Anti-reflection plate
Cut-off (rear)
3) Move the No. 1 mirror mount [7] to where
the scanning lamp inside cover has been
removed; then, remove the two screws
[8], and detach the anti-reflection plate
[9].
Caution:
When mounting the anti-reflection plate,
be sure to fit it in the cut-offs (front, rear)
of the No. 1 mirror mount securely. Fur-
ther, be sure to fit the connector in step
4) in the anti-refection plate.