COPYRIGHT
©
1999 CANON INC. CANON imageRUNNER 600 REV.1 JAN. 2000 PRINTED IN U.S.A.
13-35
CHAPTER 13 TROUBLESHOOTING
1.5±0.2mm
1.5±0.2mm
Fixing
screw
Fixing
screw
Height of the Fixing Assembly Inlet Guide
Figure 13-E201
Caution:
You would have to adjust the position of the inlet guide if you removed the inlet guide mount.
Do not loosen the fixing screw on the inlet guide to avoid adjustment. If the fixing screw has
been loosened for some reason, be sure to tighten it back in reference to the scale graduations
on the fixing assembly mount.