CHAPTER 13 TROUBLESHOOTING
13-256
COPYRIGHT
©
2000 CANON INC. CANON imageRUNNER 600 REV.1 JAN. 2000 PRINTED IN U.S.A.
Code Cause
The auto power-off circuit has an open
circuit.
The DC controller PCB is faulty.
The power supply cooling fan (1 and 2)
is faulty.
The DC controller PCB is faulty.
The wiring is faulty (short circuit, open
circuit).
The fixing assembly heat discharge fan
(FM2) is faulty.
The DC controller PCB is faulty.
The wiring is faulty (shorting, open
circuit).
The drum fan (FM8) is faulty.
The DC controller PCB is faulty.
The wiring is faulty (short circuit, open
circuit).
The pre-transfer charging assembly fan
(FM10) is faulty.
The DC controller PCB is faulty.
The wiring is faulty (short circuit, open
circuit).
The primary charging fan (FM1) is
faulty.
The DC controller PCB is faulty.
The wiring is faulty (short circuit, open
circuit).
The separation fan (FM13) is faulty.
The DC controller PCB is faulty.
The wiring is faulty (short circuit, open
circuit).
Description
The auto power-off circuit has an open
circuit.
The auto power-off signal has been
detected twice or more within 2 sec.
The lock signal (FM1LCK, FM2LCK) is
detected for 5 sec or more while the
power supply cooling fan (1 and 2) is
being driven.
The lock signal (FM2LCK) has been
detected 5 sec or more while the fixing
assembly heat discharge fan (FM2) is
being driven.
The lock signal (FM8LCK) has been
detected for 5 sec or more while the
drum fan (FM8) is being driven.
The lock signal (FM10LCK) is detected
for 5 sec or more while the pre-transfer
charging assembly fan (FM10) is being
driven.
The lock signal (FM1LCK) is detected
for 5 sec or more while the primary
charging assembly fan (FM1) is being
driven.
The lock signal (FM13LCK) is detected
for 5 sec or more while the separation
fan (FM13) is being driven.
E800
E804
E820
E823
E824
E830
E805