CHAPTER 13 TROUBLESHOOTING
13-28
COPYRIGHT
©
1999 CANON INC. CANON imageRUNNER 600 REV.1 JAN. 2000 PRINTED IN U.S.A.
9.5 Position of the Multifeeder Pickup Latching Solenoid (SL6)
A
[1]
[2]
0.4±0.2mm
0.4±0.2mm
Slide the solenoid into the direction of A to adjust so that the gap between the shutter [1] and
the shutter plate [2] is 0.4 ±0.2 mm when the solenoid is pulled.
Figure 13-D214b
Figure 13-D214a