High-performance Embedded Workshop 16. Using the Test Support Facility
REJ10J1837-0100 Rev.1.00 Nov. 16, 2008
244
debugger
E100 emulator debugger
E8 emulator software
E8a emulator software
ASMWatch ASMWatch [View -> Symbol ->
ASMWatch]
CWatch CWatch [View -> Symbol ->
CWatch]
Simulator debuggers for M16C family
Simulator debuggers for 740 family
Emulator debuggers for M16C family
Exclude the following debuggers:
- E100 emulator debugger
- E8 emulator software
- E8a emulator software
Emulator debuggers for 740 family
Exclude the following debugger:
- E8a emulator software
H8/300H Tiny series compact emulator
debugger
CPU Simulated I/O Simulated I/O [View -> CPU ->
Simulated I/O]
Coverage Coverage [View -> Code ->
Coverage]
Simulator debuggers for SuperH family
Simulator debuggers for H8SX, H8S, and H8
families
Code
Trace Trace [View -> Code ->
Trace]
Simulator debuggers for SuperH family
Simulator debuggers for H8SX, H8S, and H8
families
Emulator debuggers for SuperH family
Emulator debuggers for H8SX, H8S, and H8
families
Test items cannot be selected when the High-performance Embedded Workshop is not connected to a target.
Support of this function depends on the debugger in use. For details, refer to the user’s manual, help information, and
release notes for the emulator or simulator debugger.
16.6.2.1 Symbol-Watch (Watch window)
The following table shows information on the test-image data to be saved into test-image files and test results (not
matched).
Test group name Symbol
Test item name Watch
Test-image data to be
saved into test-image files
Values set as detailed information and the range of data in the Watch window acquired with this setting.
Check boxes for all symbols are blank by default.
Failed at symbol Name of the unmatched symbol
Src Content of the test-image file
Dest Data in the current High-performance Embedded Workshop system or in another
test-image file to be compared with
Test result details
Example Failed at symbol a[6], Src = (long)H'00002704{70000018}, Dest =
(long)H'00000daa{70000018}
To make detailed setting
If you double-click on a test item in the Create New Test Image dialog box, a further dialog box for detailed setting
opens.
The scope for all watch items to be tested must be Auto. If any other scope has been selected, the items are not shown
in the Symbols list.