Renesas REJ10J1837-0100 Network Card User Manual


 
High-performance Embedded Workshop 16. Using the Test Support Facility
REJ10J1837-0100 Rev.1.00 Nov. 16, 2008
246
Failed at symbol Name of the unmatched symbol
Src Content of the test-image file
Dest Data in the current High-performance Embedded Workshop system or in another
test-image file to be compared with
Test result details
Example Failed at symbol i, Src = (int)H'00000001{R14}, Dest = (int)H'00000000{R14}
To make detailed setting
If you double-click on a test item in the Create New Test Image dialog box, a further dialog box for detailed setting
opens.
1. To specify a symbol to be saved into the test-image file, select the checkbox for that symbol. The selected
symbol is shown in Current Setting.
2. Click OK.
16.6.2.3 Symbol-ASMWatch (ASMWatch window)
The following table shows information on the test-image data to be saved into test-image files and test results (not
matched).
Test group name Symbol
Test item name ASMWatch
Test-image data to be Values set as detailed information and the range of data in the ASMWatch window acquired with this