Toshiba H1 Series Network Card User Manual


 
TMP92CZ26A
92CZ26A-51
(3) UART data transfer format
Table 3.4.6 to Table 3.4.11 show the supported frequencies, data transfer format, baud
rate modification command, operation command, and version management
information, respectively.
Please also refer to the description of boot program operation later in this section.
Table 3.4.6 Supported Frequencies (X1)
6.00 MHz 8.00 MHz 9.00 MHz 10.00 MHz
Note: The built-in PLL (clock multiplier) is not used regardless of the oscillation frequency.
Table 3.4.7 Transfer Format
Byte Number to
Transfer
Transfer data from PC to TMP92CZ26A Baud Rate Transfer data from TMP92CZ26A to PC
1st byte
2nd byte
Matching data (5AH)
(Frequency measurement and baud
rate auto setting)
OK: Echo back data (5AH)
Error: No transfer
3rd byte
to
6th byte
Version management information
(See
Table 3.4.10)
7th byte Frequency information
8th byte
9th byte
Baud rate modification command
(See
Table 3.4.8.)
9600 bps
OK: Echo back data
Error: Error code x 3
10th byte
to
(n 4)th byte
User program
Intel Hex format (binary)
NG: Operation stop by checksum error
(n 3)th byte OK: SUM (High)
(See (4)-c).)
(n 2)th byte OK: SUM (Low)
Boot
ROM
(n 1)th byte
n’th byte
User program start command (C0H)
(See
Table 3.4.9.)
New baud rate
OK: Echo back data (C0H)
Error: Error code x 3
RAM Branch to user program start address
“Error code x 3” means that the error code is transmitted three times. For example, if the error code is 62H, the
TMP92CZ26A transmits 62H three times. For error codes, see (4)-b).