Toshiba H1 Series Network Card User Manual


 
TMP92CZ26A
92CZ26A-645
4.3 AC Characteristics
The Following all AC regulation is the measurement result in following condition, if unless otherwise noted.
AC measuring condition
Clock of top column in above table shows system clock frequency, and “T” shows system
clock period [ns].
Output level: High = 0.7 3AV
CC
, Low = 0.3 3AV
CC
Input level: High = 0.9 3AV
CC
, Low = 0.1 3AV
CC
Note: In table, “Variable” shows the regulation at DVCC3A=3.0V~3.6V, DVCC1A=DVCC1B=DVCC1C=1.4~1.6V.
4.3.1 Basic Bus Cycle
Read cycle
Variable
No. Parameter Symbol
Min Max
80 MHz 60 MHz Unit
1 OSC period (X1/X2)
t
OSC
100 166.6
2 System clock period ( = T)
t
CYC
12.5 266.6 12.5 16.6
3 SDCLK low width
t
CL
0.5T 3 3.25 5.3
4 SDCLK high width
t
CH
0.5T 3 3.25 5.3
5-1
A0 ~ A23 valid D0 ~ D15 input at 0
waits
t
AD
2.0T 18.0 7 15.3
t
AD6
6.0T 18.0
82
5-2
A0 ~ A23 valid
D0 ~ D15 input at 4 waits/6 waits
t
AD7
8.0T - 18.0 82
t
RD
1.5T 18.0
7
6-1
RD falling D0 ~ D15 input at 0 waits
t
RD
1.5T 18.0 0.75
t
RD6
5.5T 18.0
73.6
6-2
RD falling
D0 ~ D15 input at 4 waits/6waits
t
RD7
5.5T 18.0 50.75
7-1
RD low width at 0 waits
t
RR
1.5T 10 8.75 14.9
7-2
RD low width at 4 waits
t
RR6
5.5T 10 58.75 81.3
8
A0 ~ A23 valid
RD
falling
t
AR
0.5T 5 1.25 3.3
9
RD falling SDCLK rising
t
RK
0.5T 5 1.25 3.3
10 A0 ~ A23 valid D0 ~ D15 hold
t
HA
0 0 0
11
RD
rising D0 ~ D15 hold
t
HR
0 0 0
12
WAIT setup time
t
TK
3 3 5
13
WAIT hold time
t
KT
2 2 3
14 Data byte control access time
t
SBA
1.5T 18.0 0.75 7
15
RD high width
t
RRH
0.5T 5 1.25 3.3
ns
AC measuring condition
Data_bus, Address_bus, various function control signal capacitance C
L
= 50 pF
Note: The operation guarantee temprature: 80MHz: Ta=050°C, less than 60MHz: Ta=070°C