TMP92CZ26A
92CZ26A-661
4.3.9 LCD Controller
Variable
Parameter Symbol
Min Max
80 MHz
(n=0)
60 MHz
(n=0)
Unit
LCP0 clock period t
CW
2T(n+1) 25 33.3
LCP0 high width
(Include phase inversion)
t
CWH
T(n+1)
− 5 7.5 11.6
LCP0 low width
(Include phase inversion)
t
CWL
T(n+1)
− 5 7.5 11.6
Data valid → LCP0 falling
(Include phase inversion)
t
DSU
T(n+1)
− 7.5 5 9.1
LCP0 falling → Data hold
(Include phase inversion)
t
DHD
T(n+1)
− 7.5 5 9.1
Signal delay from LCP0 basic
changing point
(Include phase inversion)
t
GDL
-20 20
20 20
ns
AC measuring condition
• C
L
= 50 pF (LCP0 only C
L
= 30 pF)
Note: The “n” in “Variable” show value that is set to LCDMODE0<SCPW1:0>.
Example: If LCDMODE0<SCPW1:0>
= “01”, n=1, t
RWP
= 2T(n+1) = 2T
LCP0
t
CWH
t
CWL
t
CW
LD0~LD23
t
DHD
t
DSU
LD0~LD23 out
LVSYNC
LHSYNC
FR
LLOAD
LGOE0
LGOE1
LGOE2
t
GDL
LDINV LDINV