Usage
Information
Use this command to configure the UP and/or DOWN threshold for the scaled
metric of a tracked IPv4 or IPv6 route.
Determine the UP/DOWN state of a tracked route by the threshold for the current
value of the route metric in the routing table. To provide a common tracking
interface for different clients, route metrics are scaled in the range 0 to 255, where
0 is connected and 255 is inaccessible. The scaled metric value communicated to a
client always considers a lower value to have priority over a higher value.
The resulting scaled value is compared against the configured threshold values to
determine the state of a tracked route as follows:
If the scaled metric for a route entry is less than or equal to the UP threshold,
the state of a route is UP.
If the scaled metric for a route is greater than or equal to the DOWN threshold
or the route is not entered in the routing table, the state of a route is DOWN.
Configure the UP and DOWN thresholds for each tracked route with the
threshold metric command. The default UP threshold is 254; the default
DOWN threshold is 255. The notification of a change in the state of a tracked
object is sent when a metric value crosses a configured threshold.
The tracking process uses a protocol-specific resolution value to convert the
actual metric in the routing table to a scaled metric in the range 0 to 255. You can
configure the resolution value used to scale route metrics for supported protocols
with the track resolution ip route and track resolution ipv6 route
commands.
Related
Commands
track ip route metric threshold – configures object tracking on the threshold of
an IPv4 route metric.
track resolution ip route – configures the protocol-specific resolution value
used to scale an IPv4 route metric.
track interface ip routing
Configure object tracking on the routing status of an IPv4 Layer 3 interface.
Syntax
track object-id interface interface ip routing
To return to the default setting, use the no track object-id command.
Parameters
object-id Enter the ID number of the tracked object. The range is 1 to
500.
interface Enter one of the following values:
For a 10-Gigabit Ethernet interface, enter the keyword
TenGigabitEthernet then the slot/port information.
For a 40-Gigabit Ethernet interface, enter the keyword
fortyGigE then the slot/port information.
Object Tracking