Version Description
7.5.1.0 Introduced on the C-Series.
6.1.1.0 Introduced on the E-Series.
Example
(Index)
Dell#show rmon hc-alarm 1
RMON high-capacity alarm entry 2
object: 1.3.6.1.2.1.2.2.1.4.2099844
sample interval: 10
sample type: delta value.
value: 0, value status: positive
alarm type: rising or falling alarm.
alarm rising threshold value: positive.
rising threshold: 500, RMON event index: 3
alarm falling threshold value: positive.
falling threshold: 300, RMON event index: 4
alarm sampling failed 0 times.
alarm owner:
alarm storage type: non-volatile.
alarm status: OK
Dell#
Example (Brief)
Dell#show rmon hc-alarm brief
index SNMP OID
----------------------------------
1 1.3.6.1.2.1.1.3
2 1.3.6.1.2.1.1.3
3 1.3.6.1.2.1.1.3
4 1.3.6.1.2.1.1.3
5 1.3.6.1.2.1.1.3
Dell#
show rmon history
Display the contents of the RMON Ethernet history table.
S4820T
Syntax
show rmon history [index] [brief]
Parameters
index (OPTIONAL) Enter the table index number to display just that
entry.
brief (OPTIONAL) Enter the keyword brief to display the RMON
Ethernet history table in an easy-to-read format
Defaults none
Command
Modes
EXEC
Remote Monitoring (RMON)
1553