Version Description
8.3.11.1 Introduced on the Z9000.
8.1.1.0 Introduced on the E-Series ExaScale.
7.6.1.0 Introduced on the S-Series.
7.5.1.0 Introduced on the C-Series.
6.5.1.0 Introduced on the E-Series.
Usage
Information
Messages can contain an unlimited number of lines; however, each line is limited
to 255 characters. To move to the next line, use <CR>. To send the message use
CTR-Z; to abort a message, use CTR-C.
service timestamps
To debug and log messages, add time stamps. This command adds either the uptime or the current time
and date.
Syntax
service timestamps [debug | log] [datetime [localtime] [msec]
[show-timezone] | uptime]
To disable timestamping, use the no service timestamps [debug | log]
command.
Parameters
debug (OPTIONAL) Enter the keyword debug to add timestamps to
debug messages.
log (OPTIONAL) Enter the keyword log to add timestamps to
log messages with severity from 0 to 6.
datetime (OPTIONAL) Enter the keyword datetime to have the
current time and date added to the message.
localtime (OPTIONAL) Enter the keyword localtime to include the
localtime in the timestamp.
msec (OPTIONAL) Enter the keyword msec to include milliseconds
in the timestamp.
show-
timezone
(OPTIONAL) Enter the keyword show-timezone to include
the time zone information in the timestamp.
uptime (OPTIONAL) Enter the keyword uptime to have the
timestamp based on time elapsed since system reboot.
Defaults Not configured.