Version Description
8.3.12.0 Introduced on the S4810.
8.4.1.0 Introduced on the E-Series.
Related
Commands
show processes restartable
redundancy auto-failover-limit
Specify an auto-failover limit for RPMs. When a non-recoverable fatal error is detected, an automatic
RPM failover occurs. This command does not affect user-initiated (manual) failovers.
S4820T
Syntax
redundancy auto-failover-limit [count number [period minutes] |
period minutes]]
To disable the auto-failover limit control, use the no redundancy auto-
failover-limit command.
Parameters
count number Enter the number of times the RPMs can automatically
failover within the period defined in the period parameter.
The range is from 2 to 10. The default is 3.
period minutes Enter a duration in which to allow a number of automatic
failovers (limited to the number defined in the count
parameter). The range is from 5 to 9000 minutes. The
default is 60 minutes.
Default
• Count: 3
• Period: 60 minutes
Command
Modes
CONFIGURATION
Command
History
This guide is platform-specific. For command information about other platforms,
refer to the relevant Dell Networking OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command.
Version Description
8.3.19.0 Introduced on the S4820T.
8.3.12.0 Introduced on the S4810.
746
High Availability (HA)