Defaults none
Command
Modes
EXEC Privilege
Command
History
This guide is platform-specific. For command information about other platforms,
refer to the relevant Dell Networking OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command.
Version Description
9.7(0.0) Introduced on the S6000–ON.
9.0.2.0 Introduced on the S6000.
8.3.19.0 Introduced on the S4820T.
8.3.11.1 Introduced on the Z9000.
8.3.7.0 Introduced on the S4810.
7.8.1.0 Introduced.
Usage
Information
This command applies to both IPv4 and IPv6 CAM Profiles, but is best used when
verifying QoS optimization for IPv6 ACLs.
QoS Optimization for IPv6 ACLs does not impact the CAM usage for applying a
policy on a single (or the first of several) interfaces. It is most useful when a policy
is applied across multiple interfaces; it can reduce the impact to CAM usage across
subsequent interfaces.
The following describes the test cam-usage command shown in the following
example.
Term Explanation
Stack-Unit
Lists the stack unit or units that are checked. Entering all
shows the status for all stacks.
Portpipe Lists the portpipe (port-set) or port pipes (port-sets) that are
checked. Entering all shows the status for linecards or
stack units and port-pipes in the chassis. The port set value
is from 0 to 0.
CAM Partition Shows the CAM profile of the CAM.
Available CAM Identifies the amount of CAM space remaining for that
profile.
Estimated CAM
per Port
Estimates the amount of CAM space the listed policy will
require.
Status Indicates whether or not the policy will be allowed in the
CAM.
Content Addressable Memory (CAM)