Parameters
stack-unit Enter the stack-unit number. For the S4820T, the range is
from 0 to 11.
members Enter the keyword members for all stack-units.
Defaults Disabled (the failed switch is automatically rebooted).
Command
Modes
CONFIGURATION
Command
History
This guide is platform-specific. For command information about other platforms,
refer to the relevant Dell Networking OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command.
Version Description
9.7(0.0) Introduced on the S6000.
8.3.19.0 Introduced on the S4820T.
8.3.7.0 Introduced on the S4810.
8.3.11.1 Introduced on the Z9000.
8.3.1.0 Added the members option.
Usage
Information
Enabling this command keeps the failed switch in the Failed state. The switch does
not reboot until it is manually rebooted. When enabled, it is not displayed in the
running-config. When disabled, it is displayed in the running-config.
Related
Commands
show redundancy — displays the current redundancy status.
redundancy force-failover stack-unit
Force the standby unit in the stack to become the management unit.
Syntax
redundancy force-failover stack-unit
Parameters
stack-unit Enter the stack unit. For the S4820T, the range is from 0 to
11.
Defaults Not enabled.
Command
Modes
EXEC Privilege
Command
History
This guide is platform-specific. For command information about other platforms,
refer to the relevant Dell Networking OS Command Line Reference Guide.