Section 18 Multi-Function Timer Pulse Unit (MTU)
Rev. 4.00 Sep. 14, 2005 Page 519 of 982
REJ09B0023-0400
Item Channel 0 Channel 1 Channel 2 Channel 3 Channel 4
DMA activation TGRA_0
compare
match or
input capture
TGRA_1
compare
match or
input capture
TGRA_2
compare
match or
input capture
TGRA_3
compare
match or
input capture
TGRA_4
compare
match or input
capture
A/D converter
start trigger
TGRA_0
compare
match or
input capture
TGRA_1
compare
match or
input capture
TGRA_2
compare
match or
input capture
TGRA_3
compare
match or
input capture
TGRA_4
compare
match or input
capture
Interrupt sources 5 sources
• Compare
match or
input
capture
0A
• Compare
match or
input
capture
0B
• Compare
match or
input
capture
0C
• Compare
match or
input
capture
0D
• Overflow
4 sources
• Compare
match or
input
capture
1A
• Compare
match or
input
capture
1B
• Overflow
• Underflow
4 sources
• Compare
match or
input
capture
2A
• Compare
match or
input
capture
2B
• Overflow
• Underflow
5 sources
• Compare
match or
input
capture
3A
• Compare
match or
input
capture
3B
• Compare
match or
input
capture
3C
• Compare
match or
input
capture
3D
• Overflow
5 sources
• Compare
match or
input
capture 4A
• Compare
match or
input
capture 4B
• Compare
match or
input
capture 4C
• Compare
match or
input
capture 4D
• Overflow
[Legend]
O
: Possible
: Not possible