Section 18 Multi-Function Timer Pulse Unit (MTU)
Rev. 4.00 Sep. 14, 2005 Page 622 of 982
REJ09B0023-0400
Timing for Counter Clearing by Compare Match/Input Capture: Figure 18.60 shows the
timing when counter clearing on compare match is specified, and figure 18.61 shows the timing
when counter clearing on input capture is specified.
TCNT
Counter
clear signal
Compare
match signal
TGR
N
N
H'0000
Pφ
Figure 18.60 Counter Clear Timing (Compare Match)
TCNT
Counter clear
signal
Input capture
signal
TGR
N
H'0000
N
Pφ
Figure 18.61 Counter Clear Timing (Input Capture)