Chapter 5 Configuration Menu
> 5.3 Thin Provisioning Management
ETERNUS DX400/DX8000 series ETERNUSmgr User Guide Settings/Maintenance
272
Copyright 2010 FUJITSU LIMITED
P2X0-0760-02ENZ0
3 Select the Thin Provisioning Pool to be formatted, and click the [Set] button.
There are two methods to select Thin Provisioning Pools.
• Individual Selection (multiple selections can be made)
Select the Thin Provisioning Pools to be formatted from the Thin Provisioning Pool List.
• Range Selection
Enter the first and last Thin Provisioning Pool numbers to be formatted in the From/To
fields.
Thin Provisioning Pools displayed with a checkbox in the specified range will be
formatted.
→ The [Format Thin Provisioning Pool (Check)] screen appears.
• If selecting "All Thin Provisioning Pool" as the Mode, data in the
Thin Provisioning Volume created in the target Thin Provisioning
Pool will be deleted.
• When clicking the [Set] button in the following conditions, an error
screen appears.
- When Individual Selection is selected, and no Thin
Provisioning Pools (TPP) are specified for formatting.
- When Range Selection is selected, and both or one of the
From: TPP No. or To: TPP No. text boxes is blank.
- When Range Selection is selected, and characters other than
numeric or alphabetic characters [a] – [f] or [A] – [F] are
specified in the From: TPP No. or To: TPP No. field.
- When Range Selection is selected, and there are no TPPs
that can be formatted in the range specified with From: TPP
No. and To: TPP No..