Appendix A Screen Details
> A.6 Advanced Copy Status
ETERNUS DX400/DX8000 series ETERNUSmgr User Guide Settings/Maintenance
699
Copyright 2010 FUJITSU LIMITED
P2X0-0760-02ENZ0
• Recovery Mode
The recovery mode of the session is displayed.
- Automatic: A mode to restart copying automatically when the REC copy path has
recovered from abnormal status.
- Manual: A mode not to restart copying automatically when the REC copy path has
recovered from abnormal status.
• Split Mode
The split mode of the relevant session is displayed.
- Automatic: A mode in which Write I/O accesses to copy source are accepted when the
copy path of REC is in abnormal status.
- Manual: A mode in which Write I/O accesses to copy source are not accepted when the
copy path of REC is in abnormal status. Specified sense information is sent to the host.
• Remote Box ID
The identifier of another device which is remotely connected with this device is displayed.
■ Extent Information
● Displayed contents
• Offset
A copy number in specified range is displayed in 0 – 2048 (decimal number).
• Source LBA
The copy source Start LBA (Logical Block Address) in the specified range is displayed in 16-
digit hexadecimal.
• Destination LBA
The copy destination Start LBA (Logical Block Address) in the specified range is displayed in
16-digit hexadecimal.
• Extent Block
The number of data blocks in the specified copy range is displayed in decimal.
Units for each volume type are as follows:
- Open Volume: Block
- Mainframe Volume: Track
A.6.6 Advanced Copy Status (Advanced Copy Path Status) Screen
This screen displays the status of the path between the local and the selected remote devices.
■ Box ID Information
● Displayed contents
• Local Box ID
Displays the Box ID of this device.
• Remote Box ID
The Box ID of the selected remote device is displayed.