Fujitsu DX400 Computer Drive User Manual


 
Chapter 5 Configuration Menu
> 5.3 Thin Provisioning Management
ETERNUS DX400/DX8000 series ETERNUSmgr User Guide Settings/Maintenance
279
Copyright 2010 FUJITSU LIMITED
P2X0-0760-02ENZ0
2 Set the thresholds, and click the [Set] button.
There are two methods to specify the thresholds:
Manual setting (multiple specification can be made)
Input the threshold (%) in the Caution text box of the Volume List.
Set Range
Input the first and last volume numbers to set the threshold in the From/To fields.
Input the threshold to be changed in the Caution text box, and click the [Execute]
button.
The [Set Thin Provisioning Volume Parameters (Check)] screen appears.
When using the Set Range, and if the [Execute] button is clicked
in the following situations, an error screen appears.
- Both of or one of the "From" or "To" text boxes is blank
- A value other than alphanumeric characters (hexadecimal)
has been input as "From" and/or "To" text box
- No volumes to be the target of this function are included
between the range specified with the "From" and "To" text
boxes
- The Caution text box is blank
- A value other than numerals (1 – 200) has been input in the
Caution text box
If clicking the [Jump to Page], [Next], [Prev], or [Set] button in the
following conditions, an error screen appears. This function
performs the error checking for each page of the Volume List.
Volumes where the threshold will be changed are displayed with
a yellow background.
- The Caution text box in the Volume List is blank
- A value other than numerals (1 – 200) has been input in the
Caution text box of Volume List
If clicking the [Set] button without changing the thresholds in the
Volume List, an error screen appears.