ETERNUS DX400/DX8000 series ETERNUSmgr User Guide Settings/Maintenance
822
Copyright 2010 FUJITSU LIMITED
P2X0-0760-02ENZ0
Appendix C Syslog Message List
This chapter describes the Syslog messages that are sent by the ETERNUS DX400/DX8000
series.
C.1 Syslog Function
C.1.1 Outline
The Syslog function sends events that are detected by the ETERNUS DX400/DX8000 series to
the external
Syslog server as logs. Logs are sent using the BSD Syslog protocol that is regulated
by IETF RFC 3164.
C.1.2 Message Format
Messages that are sent by the Syslog function consist of three parts; the PRI part, the HEADER
part, and the MSG part. MSG parts consist of two fields; the TAG field and the CONTENT field.
The CONTENT field is output by the original format of the device. Each item is separated by a
comma and a space. The maximum length of an entire message is 1024 bytes.
The following table lists examples of messages and the details of formats that are output.
<14>
1
Feb 2 23:05:08
2
10.21.138.34
3
Storage:
4
Operation
5
, 1.0
6
, 0 8
7
, E8C0S20A
000002
8
, I 00020200
9
,
10
,
11
,
12
, Delete Logical Volume(s): Count=20 No=0000
0001 0002 0003 0004 0005 0006 0007 0008 0009 000A 000B 000C 000D 000E 000F
0010 0011 0012 0013
13