Appendix A Screen Details
> A.14 Set Thin Provisioning Pool Parameters
ETERNUS DX400/DX8000 series ETERNUSmgr User Guide Settings/Maintenance
736
Copyright 2010 FUJITSU LIMITED
P2X0-0760-02ENZ0
■ Set Range
● Setting item
• Set Range
- From
Input the beginning Thin Provisioning Pool number in the text box to set the thresholds.
Specify the Thin Provisioning Pool number between 0x00 – 0xFF.
- To
Input the last Thin Provisioning Pool number in the text box to set the thresholds.
Specify the Thin Provisioning Pool number between 0x00 – 0xFF.
• Threshold
- Warning
Input the Warning (high) thresholds of the Thin Provisioning Pool in percent figures (%) in
the text box.
Specify the threshold between 5 – 99 (%).
- Caution
Input the Warning (low) thresholds of Thin Provisioning Pool in percent figures (%) in the
text box.
Specify the threshold between 5 – 80 (%).
• Select threshold
Select the threshold value to be changed using the radio button.
- Both:
Specify both the Warning and Caution thresholds (Default).
- Warning only:
Specify the Warning threshold.
- Caution only:
Specify the Caution threshold.
A smaller value than the Caution threshold of the target Thin
Provisioning Pool is not allowed.
A larger value than the Warning thresh old of the target Thin
Provisioning Pool is not allowed.
• When "Both" is selected, input both the Warning and Caution
thresholds.
• When "Warning only" is selected, input the Warning threshold.