Fujitsu DX400 Computer Drive User Manual


 
Appendix A Screen Details
> A.14 Set Thin Provisioning Pool Parameters
ETERNUS DX400/DX8000 series ETERNUSmgr User Guide Settings/Maintenance
736
Copyright 2010 FUJITSU LIMITED
P2X0-0760-02ENZ0
Set Range
Setting item
Set Range
- From
Input the beginning Thin Provisioning Pool number in the text box to set the thresholds.
Specify the Thin Provisioning Pool number between 0x00 – 0xFF.
- To
Input the last Thin Provisioning Pool number in the text box to set the thresholds.
Specify the Thin Provisioning Pool number between 0x00 – 0xFF.
Threshold
- Warning
Input the Warning (high) thresholds of the Thin Provisioning Pool in percent figures (%) in
the text box.
Specify the threshold between 5 99 (%).
- Caution
Input the Warning (low) thresholds of Thin Provisioning Pool in percent figures (%) in the
text box.
Specify the threshold between 5 80 (%).
Select threshold
Select the threshold value to be changed using the radio button.
- Both:
Specify both the Warning and Caution thresholds (Default).
- Warning only:
Specify the Warning threshold.
- Caution only:
Specify the Caution threshold.
A smaller value than the Caution threshold of the target Thin
Provisioning Pool is not allowed.
A larger value than the Warning thresh old of the target Thin
Provisioning Pool is not allowed.
When "Both" is selected, input both the Warning and Caution
thresholds.
When "Warning only" is selected, input the Warning threshold.
When "Caution only" is selected, input the Caution threshold.